  • 220 Level 3 Distribution Box with Residual Current Protection

    220 Level 3 Distribution Box with Residual Current Protection

    The CHINT NB3LE RCBO is a compact and reliable protection device that combines residual current (earth leakage) and over-current protection in one unit. Designed for use in AC 50/60 Hz circuits up to 240 V, it ensures safety against overloads, short-circuits, and electric shock. ABB offers complete range of electronic residual current devices, in accordance the international Standard IEC6094 -2, Annex M. It is composed by DIN-rail mounted RD2 and RD3 relays.


  • Why do optical cables require power protection

    Why do optical cables require power protection

    To ensure its electromagnetic compatibility (EMC), a cable must be electrically shielded. This protective effect is primarily expressed by the so-called optical coverage of the shield. In principle, any electrical cable can cause or suffer electronic magnetic interference due to the coupling effect. Therefore. Optical Cables with OKM metal elements in the structure ( ply protective shell, power components, copper wire for transmitting remote power supply) must be protected against lightning and hazardous effects of electromagnetic power lines and electrified railways AC as required by the LPC 45-136. Yet, outdoors, they face temperature swings, moisture, UV exposure, rodents, and human interference. This guide covers how to. That's why you need a 100-240V AC optical power surge protector, a device designed to safeguard hybrid fiber cables from power surges, lightning strikes or switching transients.

    [PDF Version]
  • A well-known relay protection company in South Africa

    A well-known relay protection company in South Africa

    Strike Technologies has grown to be a leading South African developer, manufacturer and distributor of globally competitive Medium Voltage Protection Relays, Surge Suppression Equipment and Industrial Earth Leakage Relays. We focus on equipment that provides protection of capital assets and human. Covering all applications in medium-voltage and high-voltage protection, from overcurrent or motor to complex distance protection, our protective relays give you the safety and reliability needed to operate with confidence. Add IEC 61850 Ethernet for best-in-class interoperability and communication. Proud providers of products, installation and support of Thytronic protection and control equipment. For the first decade of its existence, Strike Technologies was founder owned. For over 45 years, NewElec has been at the forefront of motor control, delivering innovative and reliable solutions across industries such as mining, water treatment, manufacturing, and renewable energy.

    [PDF Version]
  • Arc suppression coil relay protection

    Arc suppression coil relay protection

    The devices that drive the coil are typically protected from this damage by placing a diode, MOV, or TVS suppressor across the coil. The suppressor can be embedded in the coil or installed externally in the electrical circuit or the electronic control system. In smart home panels, relays are subject to long-term and frequent operation, especially in scenarios involving AC input and load switching. Traditional MOVs (Metal Oxide. In this article I have explained the formula and techniques of configuring RC circuit networks for controlling the arcing across relay contacts while switching heavy inductive loads. With time, this condition can wear down. Arcing contacts have been the bane of industrial systems for as long as they have existed, but today systems run faster than ever before, so contact erosion becomes critical.

    [PDF Version]
  • Thermal relay protection device for mixing plant

    Thermal relay protection device for mixing plant

    Thermal overload relays are economic electromechanical protection devices for the main circuit. This article discusses an overview of a thermal relay – working with applications. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. It operates by responding to changes in temperature caused by excessive current in the circuit, preventing potential damage to equipment and ensuring smooth operation.


  • Electrical Cabinet Wiring Platform Design

    Electrical Cabinet Wiring Platform Design

    This article delves into the essential steps for creating a practical electrical cabinet, covering everything from layout principles to wiring methods. You'll learn about component division, configuration, and connection diagrams. Intelligent automatic snapping points allow parts to be easily placed in their correct location. Is an electrical cabinet drawing supposed to take hours? For most professionals, creating a proper one-line schematic means hours of manual work – from scratch or with. Accelerate electrical design for both conventional & KNX cabinets with unmatched precision, ensuring compliance and saving time. Access easy-to-edit templates and symbols to organize your projects with ease. With advanced busbar handling and cabinet visualization in 3D and 2D, E3.

    [PDF Version]
  • Sampling Principle of Relay Protection Circuit

    Sampling Principle of Relay Protection Circuit

    The principle is to grade the operating times of the relays in such a way that the relay closest to the fault spot operates first. The faster the protection operates, the smaller the resulting ha-zards, damage and the thermal stress will be. Further, the duration of the voltage. Recognized under 2(f) and 12 (B) of UGC ACT 1956 (Affiliated to JNTUH, Hyderabad, Approved by AICTE - Accredited by NBA & NAAC – 'A' Grade - ISO 9001:2015 Certified) Maisammaguda, Dhulapally (Post Via. Kompally), Secunderabad – 500100, Telangana State, India To introduce all kinds of circuit. This handbook covers the code of practice in protection circuitry including standard lead and device numbers, mode of connections at terminal strips, colour codes in multicore cables, dos and donts in execution. Also principles of various protective relays and schemes including special protection. Protective relays and devices have been developed over 100 years ago to provide “last line” of defense for the electrical systems.

    [PDF Version]
  • What are the characteristics of a current transformer CT in relay protection

    What are the characteristics of a current transformer CT in relay protection

    Current transformers (CTs) are precision devices that translate primary currents into standard secondary values for relays and meters. Correct CT selection and application directly influence: Billing accuracy: Misapplied ratio or accuracy class can cause revenue leakage or disputes. They don't measure it directly. Instead, they scale it down so your gear doesn't get fried. They help with metering, spotting faults, and keeping things under. How are current transformers used in protection systems for power grids and substations? Current transformers (CTs) are the primary sensing interfaces between high-current power circuits and the low-voltage protection and metering equipment used in substations and transmission networks.

    [PDF Version]
  • Requirements for commissioning relay protection hard-plate

    Requirements for commissioning relay protection hard-plate

    This guide explores the essential aspects of testing and commissioning relay protection panels, with a focus on practical design tips, compliance with IEC 61439 standards, and relevant calculations. Relay protection panels serve as the nerve center of electrical protection systems. This happens because the main function of protection devices is related to operation under fault conditions so these devices cannot be tested under normal operating conditions. The tests performed include: Tests in which the operating parameters of the relays, etc. Conditions such as temperature range, vibration, mechanical shock. This article is designed to address multiple facets of relay testing and commissioning.

    [PDF Version]
  • Leakage protection detection for three-level distribution boxes

    Leakage protection detection for three-level distribution boxes

    This page explains how to design and select a ground fault / leakage monitoring module that reliably detects dangerous residual currents, avoids nuisance trips and connects cleanly into smart LV panels, feeders, UPS/PCS/PV systems and protection IEDs. Implementation: Install one or more high-sensitivity leakage current protection relays on the incoming line side of each terminal distribution box (such as a lighting box or socket box). In addition to installing leakage protectors in the final switch box, a first level leakage protector should. An accurate protection of people and electrical equipment against leakage currents can be achieved by installing Residual Current Devices (RCDs) which detect an imbalance of the electrical flow and trip assuring indeed protection against earth fault, reducing the risk of death or serious injury and. There are two levels of leakage protection, which are the main circuit or sub-circuit in the main distribution box at one level and the switch box at one level. The protective electrical appliances are generally circuit breakers with leakage protection.

    [PDF Version]
  • What is 87b Relay protection tester

    What is 87b Relay protection tester

    Busbar protection (87B) works by comparing the sum of incoming and outgoing currents. In normal operation, currents are balanced. Proven high-impedance differential provides optimum speed and selectivity. Space and cost-saving configurations available featuring a. Busbar Differential Protection Definition: Busbar differential protection is a scheme that quickly isolates faults by comparing currents entering and leaving the busbar using Kirchoff's current law. Bus faults are rare but catastrophic — every connected feeder feeds fault current into a single point. The unit offers totally drawo t construction with integral test facilities. Current transformer shorting is. High impedance bus differential is a method of differential bus protection using parallel set of current transformers (CT) from each phase which is passed through a high impedance element in the protective relay.

    [PDF Version]
  • Protection level of low-voltage dense busbars

    Protection level of low-voltage dense busbars

    Busbar rating: 1600–6300 A depending on load density; consider temperature rise and ambient. Short-circuit withstand: kA rating must exceed available fault current with margin; verify bracing and tested assemblies. The IEC 61439. These requirements are necessary to keep the level of error voltage as low as possible to prevent maloperation of the relay. In addition. Rated voltage does not exceed 1 000 V AC or 1500 V DC. Generation, transmission, distribution and control of electric energy. Electrical equipment of. Figure 1: High-performance VIOX industrial low voltage switchgear assembly, demonstrating modern compartment design, reliable circuit protection, and clear busbar phase identification for superior substation safety.

    [PDF Version]
  • How to demonstrate the importance of relay protection

    How to demonstrate the importance of relay protection

    A protective relay operates by continuously monitoring electrical parameters, detecting abnormalities, making decisions, and triggering circuit breakers to isolate faulty sections. Engineering use: Relays are used on feeders, transformers, buses, motors, generators, and transmission lines to protect equipment and improve system. A protective relay is an intelligent electrical device designed to detect faults in power systems and initiate corrective actions such as tripping a circuit breaker. In this blog, we'll discuss the essentials of protective relaying, exploring how it helps maintain system. An electrically operated switch like a relay plays a key role in controlling an electrical circuit through an independent low-power signal, otherwise used where a number of circuits should be controlled through the single signal. They are intended to quickly identify a fault and isolate it so the balance of the system continue to run under normal conditions. This 12-hour instructor-led protective relay.

    [PDF Version]

More industry information

Contact Us

We Look Forward to Working with You

Contact Information

Phone +27 64 827 3915
Address Unit 9, Highveld Technopark, 43 Atlas Road, Johannesburg, 2196, South Africa

Send an Inquiry